A FINISH PEOPLE SEE. A SYSTEM THEY EXPERIENCE.
Select acoustic performance for the complete installed system.

Sound absorption reduces reflected sound within a room; sound insulation concerns transmission between spaces. Choose the relevant project requirement, then compare frequency results and mounting details. Hole area or a decorative pattern alone does not establish an absorption rating.
START WITH THE SPACE
What does the room need to feel and look like?
Workplaces and meeting rooms
Share occupancy, room layout and the designer’s sound-absorption brief. Include visible joints, screens and service access in the wall or ceiling plan.
Hospitality and shared interiors
Connect the acoustic treatment with the decor scheme, cleaning needs and areas people touch. Compare a finished panel and adjoining joint under the intended lighting.
Education and public spaces
Send the room use, installation drawings and project fire, emission and acoustic requirements. Match the proposed assembly and documentation before specifying the order.
For a ceiling, include the support arrangement and responsibility for its design. The panel quotation identifies supplied items; your installation drawings establish the complete fixing and support detail.
Let the room brief set the comparison.
Tell us whether the treatment is intended for meeting-room speech, a shared dining space, a teaching room or another use. Send the acoustic specialist’s required method and frequency-related criteria with the treatment locations. The purchase schedule can then follow the room design rather than one headline panel rating.
Coordinate lighting, cleaning access, service penetrations and joints on the same elevation. For a visible veneer or painted scheme, compare a finished joint and perimeter return with the room’s adjacent materials before setting the order reference.
Specifications
Supply specifications
Finished panel formats
Send your required width and length. We’ll discuss suitable formats for your chosen panel.
Buying components?
Include part dimensions, pattern direction, installation references and quantities by item with your drawing.
| Supply | Acoustic MDF panels; construction quoted for your project |
|---|---|
| Thickness & format | Confirmed for the pattern, finished panel and installation drawing |
| Pattern | Perforations or slots; geometry, open area and edge margins specified |
| Face & backing | Decorative finish, backing and requested components identified in quotation |
| Acoustic requirement | Target and test method specified; report matched to the proposed installed construction |
| Fire & emissions | Required classification, method and finished-construction documents specified |
Details for your application
Panel construction and finishing
| Panel drawing | Thickness, dimensions, pattern geometry, edge margins, joint alignment and item revision. |
|---|---|
| Decorative surface | Veneer, melamine or paint requirement, physical master, grain/decor direction, sheen and exposed edges. |
| System section | Backing, absorber, cavity and mounting arrangement; identify which components are requested in the supply. |
| Performance documents | Project absorption target/method, frequency results, tested construction and required fire/emission information. |
| Order schedule | Room/item references, quantities, sample/mock-up scope, pack protection and installation sequence. |
Quote the panel with the construction behind it.
A useful specification connects the visible face with the material, backing and installation detail. Include the required panel dimensions and the drawing revision for each item.
| Panel and pattern | MDF designation, thickness, panel sizes, hole diameter or slot width, spacing, open-area requirement and pattern drawing. |
|---|---|
| Visible finish | Veneer, melamine or paint requirement; physical colour/wood master, grain direction, sheen, edges and joints. |
| Backing and cavity | Requested fabric/felt or other backing, absorber material, air space and mounting arrangement in the section drawing. |
| Installation | Wall or ceiling location, support/fixing references, module layout, perimeter returns, access panels and service openings. |
| Performance and documents | Project absorption target and method, frequency data, fire classification, emission requirements and matching construction records. |
| Quoted scope | Panel-only or requested additional components, finishing, cut-outs, sample/mock-up, quantities and labelled packing. |
Thickness, finished formats, pattern geometry, backing and mounting components are quoted for the proposed item. Keep panel dimensions separate from wall coverage and any joints or installation allowances.
Describe the full section behind the visible module.
Scroll horizontally to compare all columns.
| Part of the section | Specify | Keep with the quotation |
|---|---|---|
| MDF face panel | Board designation, finished size, thickness, pattern, solid borders and decorative finish. | Item drawing, finish master and the reported panel description. |
| Acoustic backing | Specified fabric, felt or other layer, its identity and position behind the face. | The requested supplied item and its material reference. |
| Absorber and air space | Material identity, thickness, arrangement and cavity depth in the installation section. | Acoustic specification, report mounting and the complete project detail. |
| Fixing and support | Support layout, fasteners, edge/ceiling detail and service access. | Installation drawing and responsibility for the support design. |
Distinguish finished panel size from the installation module and the wall coverage. Include joint widths, perimeter gaps, returns, corner treatment and any access panels. Mark which dimensions belong to the supplied panel and which belong to the installation layout.
Keep required fire and emission documents with the proposed board, finish and backing. For a ceiling or public interior, include the project’s fixing and complete-construction requirements before selecting the visual pattern alone.
PATTERN, FINISH AND INSTALLATION
Choose a visual rhythm. Keep the system connected.
Perforated MDF panels
Specify hole shape, diameter, centres, edge margins and any pattern alignment across joints. Include the open-area requirement and the proposed backing in the same drawing.
Compare: a finished face, cut edge and two adjoining modules.Slotted or grooved acoustic panels
Identify the visible slots, rear machining and remaining webs in a section. Distinguish a decorative groove from the openings and construction required by the acoustic design.
Compare: slot geometry, rear detail, finish and mounting reference.Decorative face and backing
Discuss veneer, melamine or paint with the panel pattern. Confirm backing, absorber and cavity details, together with which components are included in the supply.
Explore veneer and matchingRequest a pattern that suits the room layout and the required performance. Compare the absorption data with the tested finish, backing and mounting arrangement; keep those references with the proposed item.
Have a drawing for a perforated or slotted part?
Send the plan and section with datums, hole/slot positions, edge distances, joint alignment and service openings. Use our MDF machining route for processing details and the cut-to-size route for item codes and quantities.
Define openings and borders with the same drawing.
Show the holes or slots, rear machining and remaining material in section. Mark fixing zones, solid borders and service openings so we can discuss the complete acoustic panel.
Across neighbouring modules, identify pattern origins and the line or pitch that must continue through the joint. Number panels on the elevation, with grain or decor arrows for woodgrain faces. Keep mirrored corner pieces and perimeter cuts distinct from repeated central modules.
Calculate open area as geometry, then request acoustic results.
For an ideal repeating square grid of circular through-holes, patterned-field open area is π × diameter² ÷ (4 × pitch²). The planning comparison below uses a 16 mm centre-to-centre pitch and excludes solid borders, service openings, backing and any blocked holes. These dimensions are calculation inputs, not published stock patterns.
Scroll horizontally to compare all columns.
| Hole diameter | Square-grid pitch | Patterned-field open area |
|---|---|---|
| 6 mm | 16 mm | 11.0% |
| 8 mm | 16 mm | 19.6% |
| 10 mm | 16 mm | 30.7% |
Open area describes the pattern geometry. To compare sound absorption, use laboratory results for the panel, backing and mounting you plan to install. Include solid borders when calculating the whole panel’s open area.
COMPARE OPTIONS
Your selection at a glance
Pattern and module
Specify holes or slots, pitch, solid borders and pattern alignment. Separate finished panel dimensions from joints and installed coverage.
Backing and cavity
Identify the backing, absorber, air space and supports in section. List which components are included in the panel order.
Acoustic and fire documents
Match results to the panel, finish and installed build-up. Keep acoustic, fire and emission requirements as separate fields.
COMPARE THE PROPOSED SYSTEM
Make the report and installation detail part of the buying decision.
Include the absorption target specified for your project. Request the matching report with its frequency results, rating method, specimen description and mounting details, alongside the panel and backing specification.
How to compare acoustic reports
ISO 354 covers measurement of sound absorption in a reverberation room. ISO 11654 provides a method for rating frequency-dependent absorption results. Ask for the method your project requires and the complete construction described by the report.
Keep the reported mounting and material references with the installation drawing. Review proposed changes to the finish, openings, backing or cavity with the project’s acoustic specialist.
For fire-retardant material, discuss the MDF grade together with the decorative face, backing and project fire classification. Request the documents for the proposed finished construction.
Ask for the method and the construction behind the result.
Scroll horizontally to compare all columns.
| Report question | Request | Match to the project |
|---|---|---|
| How was absorption measured? | Test method, frequency results and reported specimen information. | The method and frequency criteria in the acoustic brief. |
| How was a summary rating obtained? | The named rating method and supporting frequency data. | The specific required metric; do not compare unnamed numbers. |
| What construction was tested? | Panel, pattern, finish, backing, absorber, cavity and mounting detail. | The proposed purchase and installation section. |
| What else must the item meet? | Applicable fire, emission and other project documents. | The actual finished construction, destination and use. |
ASTM C423 also addresses sound absorption using a reverberation-room method. Request the standard and rating protocol specified for your project, whether an ISO-based or ASTM-based route. Keep summary ratings with their methods and frequency data instead of assuming similarly presented figures describe identical tests.
Compare acoustic reports for the proposed pattern, finish, backing, absorber and cavity. Ask the acoustic specialist to review any changes. Use a physical sample to check appearance and fit alongside those results.
Product data & reports to request
Request a technical data sheet covering:MDF grade, thickness and dimensions; pattern geometry/open area, finish and backing, with item and drawing references.Include these specification details:- Panel thickness, pattern geometry, finish and backing in the reported construction
- Absorber, cavity, mounting, tested area and arrangement relevant to the proposed installation
- Required acoustic method/rating, fire classification, emission method and destination documents
Company documents to view
FSC chain of custody Wood panels · purchase & salesISO 9001 & ISO 14001 Management systems · stated sales activitiesView our company certificates alongside the technical data for your selected panel.Acoustic MDF panel and installed-system requirements: what to match
- Panel details
- MDF grade, thickness and dimensions; pattern geometry/open area, finish and backing, with item and drawing references.
- Acoustic construction
- Project absorption target and test/rating method; report frequency results, panel/finish/backing, absorber, cavity and mounting details.
- Destination and installation
- Required fire and emission documents, wall/ceiling/support sections, supplied components, cut-outs, sample and pack/room labels.
BEFORE YOU ORDER
Ordering information
- Minimum order
- 1 container
- Production time
- 7–15 days
- Samples
- Free samples
- Delivery terms
- FOB Qingdao / Lianyungang
USD 600–1,100 / m³ FOB Qingdao / Lianyungang
CUZI · Available to order · Raw materials in stock
Made to order · Production: 7–15 days · Warranty: 180 days
Container shipping by sea. Custom specifications and sizes available; ocean freight quoted separately.
Sample freight & order notes
- Minimum order: Mixed loads available.
- Production time: Made to your order; sea transit is additional.
- Samples: Buyer pays freight; full credit on a formal order.
- Delivery terms: Container shipping by sea.
FROM A FINISH SAMPLE TO A COORDINATED ORDER
Start with the detail your client will see.
- Share the referenceSend the finish master, pattern and panel section, with the room use and acoustic specification.
- Compare a representative detailEvaluate the face, machined opening, edge and joint. Define a larger installation mock-up separately when your project needs one.
- Keep the chosen constructionRetain the sample, item drawing, backing/mounting reference and required reports with the order schedule.
Board samples are free; you pay courier freight, which is credited in full against your formal order. Specify the sample dimensions and pattern detail. Any installation mock-up and additional component scope are agreed with the project quotation.
Take the visible joint and complete section into the request.
The example below uses 8 mm holes at 16 mm pitch, an 18 mm target thickness and 600 × 1200 mm modules. Share your room, finish and mounting details so we can quote the proposed panel and discuss the relevant acoustic report.
Scroll horizontally to compare all columns.
| Project decision | Reference to keep | Start the request |
|---|---|---|
| Two adjoining perforated veneer modules | Requested hole-grid and module references; numbered positions, pattern origins, actual joint, grain/coating/edge master and backing section. Compare appearance and fit beside the required report. | Request the adjoining-module detail Request its acoustic construction file |
| Painted slotted ceiling construction | Requested FR MDF with separate finished-construction classification; pattern/bridges, backing/absorber/cavity, support/fixing responsibility, service access and project acoustic method. Identify what is supplied and installed by others. | Request the complete ceiling-section file |
| Position-labelled wall purchase | The 40-module geometric field below, reconciled with real joints, perimeter, openings, returns, access and reserves. Compare panels, backing and a more complete kit on separately stated supply lines. | Quote the acoustic wall item schedule |
Choose a detail that shows two modules meeting.
For the finish trial, include openings, an exposed edge and the adjoining joint rather than only an unmachined colour swatch. Compare pattern alignment, grain or decor, sheen and edge treatment under the intended lighting. Retain the selected face and joint with their item references.
Where an installation mock-up is needed, define its extent, support, backing, cavity and service details separately. Use it for the agreed appearance, fit and installation checks, with the laboratory documents kept alongside the proposed construction.
PROTECT THE PATTERN AND THE INSTALLATION PLAN
Help the receiving team find the right panel first.
Specify protected faces, perforated or slotted edges, backing condition and pack support. Connect item and room labels with matched sets, handed parts and installation sequence.
Discuss pack weight, unloading equipment and any separately packed components. On receipt, compare the bundle list, quantities, finish, opening geometry and visible transit condition before installation.
For FOB, confirm the shipment port; for CIF, name the destination port. Include your target receiving date and the incoming-panel checks you want recorded.
Hand the installation sequence to receiving.
Arrange labels by room or elevation and panel position, with pattern and finish arrows where needed. Keep access modules and edge pieces identifiable, and list separately supplied backing or mounting items on the packing schedule.
Check opening geometry, surface condition, backing and panel identity before installation. Compare the delivered construction with the agreed drawing and report references. Record any affected pack and position so a replacement can be connected to the correct finish and pattern set.
BUY BY ROOM, ITEM AND INSTALLATION SEQUENCE
Bring each elevation into one clear purchasing schedule.
Start with one container and combine panel lines in a mixed load. List each thickness, pattern, finish and panel size separately; identify matched sets, service openings and room references.
Regular production is 7–15 days, with shipping time additional. Confirm the schedule against the project’s pattern tooling, finish selection, samples, document requirements and final drawings.
For a distributor range, retain a master for each construction and finish. Use wholesale MDF ordering to connect item quantities, repeat purchases and destination requirements.
Compare the same acoustic panel installation.
Set panel dimensions, pattern, finish, edges and documents on the comparison schedule. List included backing, absorber, profiles, fixings and cut-outs separately, with site-supplied items visible. Compare price per delivered item and its coverage basis, rather than mixing a panel-only offer with a more complete kit.
Keep trial or mock-up work, drawing issue, pattern preparation, protection and shipping terms with each offer. Confirm the project schedule after finish and construction details are selected. For repeat rooms, retain the chosen drawing, finish and report references under the same item code.
AN INQUIRY YOUR DESIGN AND BUYING TEAMS CAN SHARE
A meeting-room wall panel brief.
Start with the elevation and the acoustic consultant’s requirement. Add a section through the face, backing, absorber and cavity, then identify the items CUZI is being asked to supply.
- Design reference
- Wall elevation, panel module, pattern across joints, corner/return details and service openings.
- Material and finish
- MDF grade and thickness, hole/slot drawing, decorative master, edges and backing arrangement.
- System requirement
- Target absorption and method, reported construction, mounting section and fire/emission specification.
- Order scope
- Panels and requested accessories, quantities by item, mock-up needs, packing sequence and destination port.
A visual mock-up lets the team review colour, joints and fitting. Match the acoustic requirement to the relevant test report and have the project specialist review the proposed installation.
Turn the elevation into individual purchase items.
A 12.0 m × 2.4 m wall fits a starting grid of 20 columns and two rows of 600 × 1200 mm modules: 40 modules covering 28.80 m². Adjust the cutting list for joints, borders, corners, openings and spares.
Scroll horizontally to compare all columns.
| Grid item | Calculation | Result |
|---|---|---|
| Columns | 12.0 m ÷ 0.6 m | 20 |
| Rows | 2.4 m ÷ 1.2 m | 2 |
| Module count | 20 × 2 | 40 |
| Nominal module area | 40 × 0.6 m × 1.2 m | 28.80 m² |
Reconcile the field with the real joint width, perimeter and service openings before pricing finished panels. Label positions by elevation, column and row; identify repeated central modules, edge cuts, access pieces and any mirrored pattern. Keep replacements or reserve pieces on their own lines.
List backing, absorber and fixing items requested from CUZI, plus the components installed by others. The quotation should state both the panel quantities and included scope. Keep the acoustic report and mounting section with the same item schedule.
Sample checklist
Review the face, the fit and the documents together.
Use the same item reference for the sample, drawing and proposed assembly. Record the visual and dimensional checks separately from laboratory acoustic results.
Open the acoustic MDF project worksheet
| Check | What to record |
|---|---|
| Project and item | Room use, wall/ceiling location, item code, drawing revision and required performance specification. |
| Panel and openings | MDF designation, thickness, finished size, pattern, open-area basis, hole/slot dimensions and edge margins. |
| Face and joint | Finish master, grain/decor direction, sheen, openings, cut edges and appearance across adjoining modules. |
| Backing and mounting | Fabric/felt, absorber, cavity, supports/fixings, supplied components and installation section. |
| Performance documents | Report identity, frequency results, rating/method, tested construction, fire/emission documents and proposed changes. |
| Order and packing | Accepted sample, quantities by item, pattern/set labels, service cut-outs, protection and installation sequence. |
| Pattern calculation | Hole/slot geometry, pitch and the area basis; repeating field or whole panel, including borders and openings. |
| Installation handover | Supplied versus site items, panel labels, joint/module dimensions, fixing references and replacement pieces. |
FAQ
Acoustic MDF buying questions.
Does CUZI supply acoustic MDF panels?
Yes. Send your pattern, finish, room use and acoustic specification. Panel dimensions, MDF grade, backing and the requested supply scope are confirmed with the project quotation.
Can I request perforated or slotted MDF?
Yes. Include hole or slot geometry, spacing, edge margins, the section drawing and pattern alignment across joints. Define the backing and mounting arrangement for the acoustic application.
Which thicknesses and panel sizes can I order?
Send the required finished dimensions and thickness with the pattern and installation drawing. Formats, tolerances and the suitable MDF construction are quoted for the proposed item.
How do I specify acoustic performance?
Specify the required absorption target and test or rating method, then compare frequency results for the complete installed construction. The report should identify the pattern, panel thickness, finish, backing, absorber, cavity and mounting. Hole area alone is not an absorption rating, and absorption is not sound insulation between rooms.
Does the panel quotation include felt, insulation and fixing components?
Backing felt, absorber and fixings are included when itemised in the quotation. Separate panel-only supply from the complete installed system, and identify who supplies each layer and support. Keep the same component identities and cavity dimensions in the acoustic report and installation section.
Can I request a veneer, melamine or painted finish?
Yes. Veneer, melamine or paint can be specified with the acoustic panel. Include the finish and edge detail in the reported construction; do not block the intended openings during finishing. Match adjoining modules using a physical finished sample and the numbered elevation.
Can I request a sample before the container order?
Yes. Board samples are free; you pay courier freight, which is credited in full against your formal order. Include the sample dimensions, pattern, finish and any larger mock-up requirements.
What should I send for a FOB or CIF project quote?
Send your item drawing, pattern and finish, proposed backing/mounting, performance documents, quantities and destination port. Add the target receiving date and packing/installation sequence.
How do I specify acoustic MDF panels?
Send the room use, panel and installation drawings, pattern, finish and absorption target. Request the matching system report and identify backing, mounting components and quantities in the supplied scope.
Further reading: Plywood cutting lists: dimensions, grain direction and yield or Incoming Panel Inspection: Counts, Checks and Release. Compare your shortlisted panels.
BRING THE DRAWING. WE’LL HELP DEFINE THE PANEL ORDER.
Start your acoustic MDF project quotation.
A room elevation, pattern reference or simple item list is enough to begin. Add the technical specification you have and use this outline to coordinate the next detail.
Open the acoustic MDF inquiry outline
I would like a quotation for Acoustic MDF Panels. Application / destination: Thickness / sheet or finished part size: Pattern / finish / elevation drawing: Backing / absorber / air gap / mounting: Acoustic, fire or emission requirements: Quantity / mixed-load items / spares: Samples or product documents needed: Packing / FOB or CIF port / required date:
Explore the next detail
- Plywood cutting lists: dimensions, grain direction and yield
- Incoming Panel Inspection: Counts, Checks and Release
- Panel storage and acclimatization: plan the workshop handover



